Do ventilatory parameters influence outcome in patients with severe acute respiratory infection? Secondary analysis of an international, multicentre1…
2021
Purpose: To investigate the possible association between ventilatory settings on the first day of invasive mechanical ventilation (IMV) and mortality in patients admitted to the intensive care unit (ICU) with severe acute respiratory infection (SARI). Materials and methods: In this pre-planned sub-study of a prospective, multicentre observational study, 441 patients with SARI who received controlled IMV during the ICU stay were included in the analysis. Results: ICU and hospital mortality rates were 23.1 and 28.1%, respectively. In multivariable analysis, tidal volume and respiratory rate on the first day of IMV were not associated with an increased risk of death; however, higher driving pr…
Ventilation Rates and Unsatisfied Percentage from Indoor CO2 Concentration
2010
This work reports the results of a survey carried out on a hall in a historic building in Palermo (Italy) with the aim of assessing the air quality by means of objective measurement of carbon dioxide (CO2) concentration and its subjective evaluation through a questionnaire. The measured values of CO2 concentration were compared with those evaluated using the Meckler equation under steady-state conditions, having verified necessary parameters such as the constancy of the indoor and outdoor CO2 levels and the uniformity of the CO 2 generation rate for all the occupants. The positive correspondence between measured and calculated results allowed us to utilise, under differing circumstances, t…
A System of <m:math display='block'><m:mrow><m:mi>P</m:mi><m:msub><m:mi>a</m:mi><m:mrow><m:msub>…
1976
A newly developed system of \(P{a_{{O_2}}}\)-controlled automatic ventilation is reported on. \({P_{{O_2}}}\) microelectrodes (Beckman, IBC) are used to measure arterial \({P_{{O_2}}}\) continuously. In a feedback control system the inspiratory O2 concentration of a respirator is adjusted as long as the set point and actual value of the arterial \({P_{{O_2}}}\) correspond. The functional behavior of the feedback control system is described.
Long-term volume-targeted pressure-controlled ventilation: sense or nonsense?
2017
The technology underlying the development of novel ventilatory modes for long-term noninvasive ventilation of patients with chronic hypercapnia is continuously evolving. Volume-targeted pressure-controlled ventilation is a hybrid ventilation mode designed to combine the advantages of conventional ventilation modes, while avoiding their drawbacks. However, manufacturers have created different names and have patented algorithms and set-up variables, which can result in confusion for physicians and respiratory therapists. In addition, clear evidence for the superiority of this novel mode has not yet been established. These factors have most likely hindered more widespread use of this mode in c…
Ventilation rates and unsatisfied percentage from indoor CO2 concentration.
2011
This work reports the results of a survey carried out on a hall in a historic building in Palermo (Italy) with the aim of assessing the air quality by means of objective measurement of carbon dioxide (CO2) concentration and its subjective evaluation through a questionnaire. The measured values of CO2 concentration were compared with those evaluated using the Meckler equation under steady-state conditions, having verified necessary parameters such as the constancy of the indoor and outdoor CO2 levels and the uniformity of the CO2 generation rate for all the occupants. The positive correspondence between measured and calculated results allowed us to utilise, under differing circum- stances, t…